SOLARY SD605 Button-Controlled Flow Tester

SOLARY SD605 brings convenient flow selection to everyday workshop inspections.

65WPower
DC12VInput Voltage
18-23psiOutput Pressure
  • Four output choicesSelect 2, 4, 6 or 8 L/min through the metal buttons.
  • Adjustment in both modesChange the selected flow in air-only testing or smoke testing.
  • Built-in pump and DC12V inputOperate without an external air compressor; the specified input voltage is DC12V.

For repair workshops, distributors and importers.

Flexible Flow for Busy Shops

Make output adjustment part of a simple daily routine with the SOLARY SD605 smoke leak detector. Metal buttons select 2/4/6/8 L/min in air and smoke modes, while the compact hanging body helps keep the work area organized. Choose a practical flow-selection model for your workshop or diagnostic equipment range.

Input voltage: DC12V. Power: 65W. Operating mode: Air&smoke mode.

Request SD605 Pricing

Built for Daily Use

  • Four selectable flow settings: choose 2/4/6/8 L/min for convenient output control.
  • Focused smoke inspection: trace visible smoke escaping from the prepared test section.
  • Air&smoke mode: choose air delivery or visible smoke for the required procedure.
  • Built-in air pump: no external air compressor required for the machine’s air supply.
  • Compact hanging design: position the tester using the supplied hook.

Control Within Easy Reach

Select one of four delivery settings directly from the panel. SD605 focuses on flow choice and dual-mode operation, with no pressure gauge or oil-level window. Its metal buttons make cleanup easier, while the supplied hook supports convenient positioning near the test area.

Less Cleanup. More Convenience.

Easy-to-wipe metal buttons help reduce oil and grime buildup around the controls. Hang the compact body from the supplied hook to keep it conveniently positioned near the inspection area. Built-in overheat protection stops the entire machine if overheating occurs and automatically resumes operation after cooling.

Trace Hidden Leaks

Use SD605 for intake leak testing, vacuum leak inspection and compatible vehicle pipework checks under the applicable service procedure. Visible smoke helps direct attention to unintended openings around hoses, fittings and seals, supporting a more focused inspection before repair decisions. For EVAP leak testing and other pressure-sensitive circuits, confirm the required setup and permitted test pressure. The 18-23psi catalog output-pressure value is not a universal vehicle test setting.

Technical Specifications

Model SD605
Input Voltage DC12V
Power 65W
Output Pressure 18-23psi
Air Supply Built-in Air Pump
Operating Mode Air&smoke mode
Output Flow 2/4/6/8 L/min
Pressure Display Not included
Flow Meter Not included
Oil-Level Window Not included
Test Oil Max Capacity 30ml
Product Size 137X200X193mm
Package Size 250X230X220mm
Gross Weight 2.8kg
Standard Accessories A+B+C

Standard Accessories

Power cord 1 set
Pipe 1 pc
Cone adapter set 1 pc
Pipe adapter 1 pc
Refueling bottle 1 set
Hook 1 set
Valve core wrench 1 set
EVAP adapter 1 pc
Inlet port adapter 1 set
Round plug set 1 set

Prepare for the Next Test

Use recommended baby oil (BB oil): 20ml for first use, then refill with 30ml only after the previous oil has been used up. Do not exceed the 30ml maximum capacity. Smoke normally begins in approximately 10 seconds after activation; this is startup time, not a promised diagnosis time. Follow the model instructions for preparation, DC12V input connection and operation.

Buyer Questions

Why choose SD605 for my workshop?

Select one of four delivery settings directly from the panel. SD605 focuses on flow choice and dual-mode operation, with no pressure gauge or oil-level window. Its metal buttons make cleanup easier, while the supplied hook supports convenient positioning near the test area.

What input voltage does SD605 require?

The specified input voltage is DC12V, with a power rating of 65W.

Which modes and flow settings are available?

Air&smoke mode. Select 2/4/6/8 L/min in air and smoke modes. These are selected output settings, not readings from an independent flowmeter.

How can I monitor pressure and oil?

This model does not include a pressure gauge. An oil-level window is not included.

What is the packaged weight?

SD605 has a catalog gross weight of 2.8kg. This is the gross weight, not the machine’s net weight.

What happens if the machine overheats?

Overheat protection stops the entire machine. Operation automatically resumes after cooling. The operator must still monitor the test.

How do I request a wholesale or OEM quote?

Send the model SD605, required quantity, destination country and logo or packaging requirements. SOLARY will confirm available options, pricing, package contents and estimated dispatch time.

Find Your Workshop Fit

Compare SD604 Hanging Pressure-Gauge Tester and SD606 Smoke Detector with Pressure Gauge, or explore our automotive smoke leak detectors to choose the configuration that fits your requirements.

Factory Support for Your Order

Buying for a workshop, distribution business or equipment brand? SOLARY welcomes enquiries from automotive equipment distributors, wholesalers and importers. Explore our manufacturing and OEM/ODM services and confirm available branding and packaging options for your order.

Request Your SD605 Quote

Equip your workshop—or expand your diagnostic equipment range—with the SOLARY SD605. Share your required quantity, destination country, intended use and any logo or packaging requirements so we can prepare a quotation. Our team will confirm the configuration, package contents, pricing and estimated dispatch time.

RFQ details: Model SD605 · Quantity · Destination country · Workshop use or resale · Branding / packaging requirements

Request a Quote

Technical reading: EPA background on vehicle evaporative emissions. This resource explains emissions background; it does not certify this product or specify its operating procedure.

Reviews

There are no reviews yet.

Be the first to review “SOLARY SD605 Button-Controlled Flow Tester”

Your email address will not be published. Required fields are marked *