Flexible Flow for Busy Shops
Make output adjustment part of a simple daily routine with the SOLARY SD605 smoke leak detector. Metal buttons select 2/4/6/8 L/min in air and smoke modes, while the compact hanging body helps keep the work area organized. Choose a practical flow-selection model for your workshop or diagnostic equipment range.
Input voltage: DC12V. Power: 65W. Operating mode: Air&smoke mode.
Built for Daily Use
- Four selectable flow settings: choose 2/4/6/8 L/min for convenient output control.
- Focused smoke inspection: trace visible smoke escaping from the prepared test section.
- Air&smoke mode: choose air delivery or visible smoke for the required procedure.
- Built-in air pump: no external air compressor required for the machine’s air supply.
- Compact hanging design: position the tester using the supplied hook.
Control Within Easy Reach
Select one of four delivery settings directly from the panel. SD605 focuses on flow choice and dual-mode operation, with no pressure gauge or oil-level window. Its metal buttons make cleanup easier, while the supplied hook supports convenient positioning near the test area.
Less Cleanup. More Convenience.
Easy-to-wipe metal buttons help reduce oil and grime buildup around the controls. Hang the compact body from the supplied hook to keep it conveniently positioned near the inspection area. Built-in overheat protection stops the entire machine if overheating occurs and automatically resumes operation after cooling.
Trace Hidden Leaks
Use SD605 for intake leak testing, vacuum leak inspection and compatible vehicle pipework checks under the applicable service procedure. Visible smoke helps direct attention to unintended openings around hoses, fittings and seals, supporting a more focused inspection before repair decisions. For EVAP leak testing and other pressure-sensitive circuits, confirm the required setup and permitted test pressure. The 18-23psi catalog output-pressure value is not a universal vehicle test setting.
Technical Specifications
| Model | SD605 |
|---|---|
| Input Voltage | DC12V |
| Power | 65W |
| Output Pressure | 18-23psi |
| Air Supply | Built-in Air Pump |
| Operating Mode | Air&smoke mode |
| Output Flow | 2/4/6/8 L/min |
| Pressure Display | Not included |
| Flow Meter | Not included |
| Oil-Level Window | Not included |
| Test Oil Max Capacity | 30ml |
| Product Size | 137X200X193mm |
| Package Size | 250X230X220mm |
| Gross Weight | 2.8kg |
| Standard Accessories | A+B+C |
Standard Accessories
| Power cord | 1 set |
|---|---|
| Pipe | 1 pc |
| Cone adapter set | 1 pc |
| Pipe adapter | 1 pc |
| Refueling bottle | 1 set |
| Hook | 1 set |
| Valve core wrench | 1 set |
| EVAP adapter | 1 pc |
| Inlet port adapter | 1 set |
| Round plug set | 1 set |
Prepare for the Next Test
Use recommended baby oil (BB oil): 20ml for first use, then refill with 30ml only after the previous oil has been used up. Do not exceed the 30ml maximum capacity. Smoke normally begins in approximately 10 seconds after activation; this is startup time, not a promised diagnosis time. Follow the model instructions for preparation, DC12V input connection and operation.
Buyer Questions
Why choose SD605 for my workshop?
Select one of four delivery settings directly from the panel. SD605 focuses on flow choice and dual-mode operation, with no pressure gauge or oil-level window. Its metal buttons make cleanup easier, while the supplied hook supports convenient positioning near the test area.
What input voltage does SD605 require?
The specified input voltage is DC12V, with a power rating of 65W.
Which modes and flow settings are available?
Air&smoke mode. Select 2/4/6/8 L/min in air and smoke modes. These are selected output settings, not readings from an independent flowmeter.
How can I monitor pressure and oil?
This model does not include a pressure gauge. An oil-level window is not included.
What is the packaged weight?
SD605 has a catalog gross weight of 2.8kg. This is the gross weight, not the machine’s net weight.
What happens if the machine overheats?
Overheat protection stops the entire machine. Operation automatically resumes after cooling. The operator must still monitor the test.
How do I request a wholesale or OEM quote?
Send the model SD605, required quantity, destination country and logo or packaging requirements. SOLARY will confirm available options, pricing, package contents and estimated dispatch time.
Find Your Workshop Fit
Compare SD604 Hanging Pressure-Gauge Tester and SD606 Smoke Detector with Pressure Gauge, or explore our automotive smoke leak detectors to choose the configuration that fits your requirements.
Factory Support for Your Order
Buying for a workshop, distribution business or equipment brand? SOLARY welcomes enquiries from automotive equipment distributors, wholesalers and importers. Explore our manufacturing and OEM/ODM services and confirm available branding and packaging options for your order.
Request Your SD605 Quote
Equip your workshop—or expand your diagnostic equipment range—with the SOLARY SD605. Share your required quantity, destination country, intended use and any logo or packaging requirements so we can prepare a quotation. Our team will confirm the configuration, package contents, pricing and estimated dispatch time.
RFQ details: Model SD605 · Quantity · Destination country · Workshop use or resale · Branding / packaging requirements
Technical reading: EPA background on vehicle evaporative emissions. This resource explains emissions background; it does not certify this product or specify its operating procedure.

















Reviews
There are no reviews yet.